Home
Office
|
PO
Box 968
Gonzalez,
FL 32560
Phone
(850) 968-5500
Fax
(850) 968-9100
cbm@cbmetcalf.com
|
|
|
Birmingham
Office
|
PO
Box 968
Gonzalez,
FL 32560
Phone
(205) 856-2539
Cell
(256) 466-7176
Fax
(850) 968-9100
jadams1084@aol.com
|
|
|
Hours
|
8:00
AM - 4:30 PM Central
|
|
|
|
|
ZOOK Burst Sensors &
Alarm Monitoring
|
|

BA Rupture Disk Burst Sensor
|

Features:
-
Electrically conductive
-
Mounts between two support rings
insulated from piping
-
Installs on vent side of the disk
holder
-
Requires minimal space (less than
1/8" thick, including gaskets)
-
Adapts to virtually all makes/types
of rupture disks, including graphite types
-
Fits easily into existing pipe
systems
-
Reusable and replaceable
-
Optional leak detection for damaged
rupture disks or fugitive emissions from relief
valves or atmospheric designed systems
|
ZENSOR Rupture Disk Burst Sensor
|

Features:
-
Rugged design withstands rough
handling and severe service conditions
-
Rupture disks and tantalum sensing
element are PTFE-coated for maximum corrosion
resistance
-
Rupture disk and sensing element are
integral parts of the electrical circuit to
eliminate false readings
-
Sensing element mounts on the vent
side of the disk
-
Shipped complete, including gaskets,
ready for easy installation
|
ZM2 Rupture Disk Alarm Monitor
|

Features:
-
Factory Mutual approved as having
intrinsically safe output for Class I, II, and III,
Division 1, Groups A, B, C, D, E, F, and G hazardous
locations
-
Factory configured for latching
operation and 115 VAC. Each channel can be
independently changed to non-latching
-
Failsafe design
-
Enclosure: NEMA Type 12,
constructed of 14 gauge steel with continuously welded
seams and oil resistant seals
-
Provides audio and visual signals for
each channel, with output relays
-
Contains front panel push buttons for
testing and resetting each channel. This function
can also be performed remotely
-
Field replaceable sense module
-
Dimensions: 11 1/2" H × 8
1/4" W × 4" D
-
Intrinsically safe sensing signal
level: 6 VDC @ 7.5 mA max.
-
Operating voltage: 115/230 VAC @
50/60 Hz; 12 VDC
-
Monitor sensing level: Open
(ruptured) 200 ohm or greater
-
Output relay contacts: 1 normally
open and 1 normally closed for each channel rated 3
amps, 120 VAC (resistive)
-
Operating temperature: -15°F to
140°F
|
|
|